TSY-2
Geotextile effective pore size analyzer (wet sieve method)
This instrument is suitable for the determination of the effective aperture of all types of geotextile products.
GB/T17634-1998
"Determination of effective pore size of geotextiles and related products - Wet sieve method"
Standard requirements for the instrument.
Test principle:
The sample and the graded granular material are sprayed with water at a predetermined vibration frequency and amplitude by using a single layer of geotextile without tension and a sample of the related product as a screen to pass the sample of the particulate material through the sample. The effective pore size of the sample is indicated by the passing particulate material and the specific particle size.
Technical Parameters:
1
, gripper inner diameter: Φ
176mm
2
Vibration frequency:
50Hz
3
Vibration amplitude:
1. 5mm
(vibration height
3mm
)
4
, time setting: two files
0 ~ 99. 99s
0
~
99
Minute
59s
5
, matching motor:
2800r/min 550W
6
,Electricity
source:
380V
7
,Dimensions:
680
×
420
×
750mm
8
,weight
the amount:
50Kg
Instrument structure and working principle:
1
, appearance (see Figure 1, outline drawing)
Instrument from the bottom plate
l
Cover
2
, the holder and the screening device, the spray system, etc.
Bottom plate
1
The four corners are provided with mounting slots, which can be fixed to the foundation or the workpiece table by screws.
,
Cover
2
The upper left control area is equipped with a counter
17 .
switch
15
Start button
16
. The cover and the screening vibration device are not in direct contact, reducing the effects of vibration.
The sprinkler system is mounted on the pillar on the right side of the floor, by the water inlet
14
Steam switch
1 3
,Metal Hose
11.
Shower head
10
Composition, the shower head is equipped with a splash cover
9
, when used, the shower head is placed in a transparent cover
8
Inside, cover the splash cover and fasten the clip
7
To prevent water from spilling out. Collection tank
5
With vibrating head
4
Rigid connection with collection tube on the left
3
, collecting groove bottom matching support grid
18
The sample is tiled on the grid. Holder
6
Press it tightly, then use the flip bolt and the cover bolt
12
Press tight.
The specific operation method of turning the bolt and opening the bolt is: due to the collecting tank
5
With gripper
6
The anti-seepage water requirement is that the outer wall is provided with a sealing ring, so there are two opening cap bolts with a long slot, when the holder
6
When it is difficult to remove, the cover bolt can be rotated in reverse, and the bayonet will lift the holder for easy operation.
? , transmission system:
The eccentric wheel is driven by the attached concrete vibrator through the belt and the gear to drive the vibrating head to generate a certain vibration frequency and amplitude vibration. All the transmission components are mounted on a flat plate, and the flat plate and the bottom plate are supported by four spring damper columns. The vibrating head and the plate are also connected by a spring damper column to reduce the impact of vibration on the instrument.
3
Electrical control
See Figure 2, electrical schematic
External environment:
1
The workbench is flat, stable, and has good anti-vibration performance.
2
Is isolated from instruments that are sensitive to vibration.
3
,temperature
10
~
30
°C
Humidity ≤
80%
4
,power supply:
Ac380V
±
10% 50Hz
5
External water supply must be regulated water source (recommended
300KPa
Flow under pressure
500mL
/
Min
)
Steps:
1
Remove the gripper
6
, flattening the sample without any force on the support grid
18
Upper, then press it with the gripper and the sample should be level.
2
The granular material selected according to the standard is evenly spread on the sample.
3
, turn on the power, turn on the power at the switch
15
.
4
At the timer
17
Set the power on time (press
GB
/
T17634-1998
Standard can be set to
600
Second, the instrument timer has two timing functions, which can be set to
0~99.99s
with
0
~
99
Minute
59s)
.
5
,water intake
14
Externally regulated water source, the shower head
10
Place a transparent cover
8
Inside, cover the splash cover and fasten the clip
7
, open the flow control valve
1 3
, spray water on the sample.
6
Press the start button
16
,start testing.
7
Passing the sample particles from the collection tank
3
Flow out and collect it.
8
After the set time has elapsed, stop the instrument from vibrating.
9
Collect untreated particulate material and sample.
10
Test results
GB/T17634-1998
Standard processing.
11
After the instrument is finished, turn off the power and clean the instrument:
Precautions:
l
The instrument has a certain vibration frequency when it works, and the workbench must be isolated from other equipment.
2
If sand is used as the test granule, please pay attention to the cleaning work of the instrument.
3
After the test is over, please clean the water and debris in the instrument.
4
Lubricate the eccentric shaft and the support spring, as well as other moving parts.
DC meter for solar power multi-channel monitoring. This is a multi-channel power measuring system with LCD display and Modbus RTU communication, available 9 DC channels or 21 channels with an external module provides current, voltage, frequency and bi-directional energy electricity parameters. It`s a perfect measuring component for the renewable power generation industry such as wind power, PV solar power etc.